AP-MALDI UHR Imaging Source
University Of Edinburgh
This goods contract from University Of Edinburgh is closed to new bids. It was awarded to KR Analytical Ltd for £101,780 on 11 Nov 2026. Region: Scotland. Procedure: Award procedure without prior publication of a call for competition.
Live now: tenders like this
- Supply and Delivery of Alternative Light Source EquipmentScottish Police AuthorityCloses 14 December 2026
- Cross Scaling Imaging PlatformUniversity Of WarwickCloses 25 November 2026
- DLSITT1106 - Upstream & Downstream Pumping Modules for Straights I02,I03,|I04,I07,I11,I19 & I24 for Diamond Light SourceDiamond Light Source Limited£320,000 · Closes 11 December 2026
- Dynamic Purchasing System for Data Sources and Services including Expertise (DPS Data SaSiE)Office of National Statistics£19,000,000 · Closes 3 April 2028
- In-Vitro Diagnostics, Point of Care Testing & Pathology Services Project_1717Supply Chain Coordination Limited£703,101,796 · Closes 16 December 2026
Get tenders like this by email
New tenders like this one, in your inbox every morning. Starts with 14 days of Pro, no card needed.
Unsubscribe in one click. See our privacy policy.
Key details
Procurement
Description
The University of Edinburgh is seeking to award KR Analytical Ltd the contract for the purchase of a MassTech Atmospheric Pressure Matrix Assisted Laser Desorption Ionisation Ultra High Resolution Source (AP-MALDI UHR).
Full description
The MassTech AP-MALDI UHR is required to provide high-resolution tissue-imaging capability (5–20 µm) on the University's existing Thermo Scientific Orbitrap Exploris 240 and Orbitrap Stellar mass spectrometers. It is the only source identified as compatible with the existing instruments' ion interfaces, acquisition controls and operating software, enabling seamless integration with established workflows.
The system provides the specialist functionality required for molecular tissue imaging, including controlled tissue scanning, a small laser spot, optical sample observation and synchronised data acquisition to facilitate the reconstruction of molecular images. Its interchangeable design also allows the Exploris 240 to retain its existing LC-MS functionality when the MALDI source is not in use.
No alternative solution has been identified that meets the combined technical, compatibility and integration requirements of the proposed application. The MassTech AP-MALDI UHR is therefore considered the only currently identified solution capable of meeting the University's immediate requirements.
Awarded supplier
Contact
Identifiers
Explore related tenders
External ID: fts-ocds-h6vhtk-07ba53 • Added 12 November 2026