In Vivo Imaging System
London School of Hygiene & Tropical Medicine
This tender has closed
The submission deadline for this contract has passed. There may be more active goods tenders from London School of Hygiene & Tropical Medicine, and hundreds more across the UK public sector.
Get tenders like this by email
New tenders like this one, in your inbox every morning. Starts with 14 days of Pro, no card needed.
Unsubscribe in one click. See our privacy policy.
Key details
Procurement
- 33110000 Imaging equipment for medical, dental and veterinary use
- 33100000 Medical equipments
- 33111000 X-ray devices
- 33111800 Diagnostic X-ray system
What happened
London School of Hygiene & Tropical Medicine awarded this contract to PerkinElmer LAS (UK) Limited on 16 Feb 2023.
Description
Purchase of a ultra-high resolution optical imaging system including highly sensitive fluorescence and bioluminescence in vivo imaging, 3D Fluorescence and tomography and X-ray computed Tomography (CT) to be delivered, installed and commissioned in LSHTM Keppel Street, London, WC1E 7HT by March 2023.
Full description
Purchase of ultra-high resolution optical imaging system including highly sensitive fluorescence and bioluminescence in vivo imaging, 3D Fluorescence and tomography and X-ray computed Tomography (CT) to be delivered, installed and commissioned in LSHTM Keppel Street, London, WC1E 7HT by March 2023.
The solution can be a single combined system or two complimentary systems. The system must be flexible, upgradable, easy to maintain and intuitive to learn.
The in vivo imaging system must be capable of the following;
- Highly sensitive 2D fluorescence and bioluminescence in vivo imaging. 4 magnification settings, the ability to image 10 mice simultaneously (with temperature and anaesthesia control), and computer-regulated narrow band-pass excitation filters covering the range of 300-900 nm.
- 3D-tomographic reconstruction for both bioluminescence and fluorescence using real CT data to create a non-uniform light absorption/scattering map. The 3D reconstruction to correct for non-uniform light absorption/scattering by different organs/tissue allowing for non-invasive and much more precise assessment of heart, GI tract and CNS infections.
- The X-ray CT facility must be able to combines scan times down to 5 seconds for total body mouse imaging, ultra-low X-ray dosage (down to 2 mGy), and an ability to image 4 mice simultaneously.