eTenders Ireland

LA2891C - TCD - RFT for the Supply of Two Dimensional Gas Chromatograph with a Mass Spectrometer and a Flame Ionisation Detector (GC GC - FID and MS)

Education Procurement Service (EPS)

Awarded
IE
supplies
Ireland

This tender has closed

The submission deadline for this contract has passed. There may be more active supplies tenders from Education Procurement Service (EPS), and hundreds more across the UK public sector.

Key details

Contracting authority
Region
Ireland
Contract value
€140,000ex VAT
Submissions closed
26 June 2024
Published
4 June 2024

Procurement

Contract period
Until 13 March 2030
60 months
Procedure type
Open Procedure
Evaluation method
MEAT
CPV classifications
  • 38000000 Laboratory, optical and precision equipments (excl. glasses)
  • 38432200 Chromatographs
  • 38432210 Gas chromatographs
  • 38433000 Spectrometers
  • 38433100 Mass spectrometer

What happened

Education Procurement Service (EPS) awarded this contract to Elementec worth €139,985 on 13 Mar 2025. The contract runs until 13 Mar 2030.

Description

Trinity College Dublin are sought for the supply and delivery of a Two-Dimensional Gas Chromatograph with a Mass Spectrometer and a Flame Ionization Detector (GC GC – MS and FID) for Trinity College Dublin (TCD). A state-of-the-art instrument (or suite of instruments) is required to perform identification and quantification of specific hydrocarbon types and polar species composition of liquid fuels, including petroleum distillates, crude oils and extending to fuels that result from experimental synthetic processes, in general accordance with ASTM D4054. The methodology of hydrocarbon compositional analysis MUST be in accordance with the standard procedure described in UDR Method – FC – M – 101 and the quantification of polar species MUST be in accordance with the standard procedures described in UDR Method – FC – M – 102. These standard procedures and methodologies are drafted by the Energy and Environmental Division of the University of Dayton Research Institute (UDRI), Dayton. Additionally, the instrument MUST be able to perform quantification of hydrocarbon types and components according to the standard procedures in ASTM D8396. The instrument MUST be equipped with a Flow Modulator connected between the primary and the secondary column. The two-dimensional GC system MUST be provided with a Mass Selective Detector, preferably a single quadrupole mass spectrometer.

Awarded supplier

Supplier
Elementec
Award value
€139,985
Award date
13 March 2025

Contact

Procurement contact for this buyer (from their other notices)